tpiTok ples

 

Kontena bilong putim bateri

Ol Polinovel bateri stoa kontena i save givim ol hai-kapasiti LFP bateri blok bilong ol yutiliti-skel na ol bikpela C&I eneji stoa projek. Ol i wokim olsem ol DC-sait bateri kontena, na ol i sapotim fleksibel PCS matsing, 'scaleble multi-container deployment, na gutpela 'liquid-cooled operesen bilong sola, win, grid, na indastrial eneji stoa aplikesen.
Ol kontena bilong putim ol betri bilong ol projek bilong eneji we ol i ken skruim

 

  • Moa pawa insait long wanpela standet kontena

    Ol Polinovel bateri stoa kontena i save bungim ol LFP bateri rak, BMS, thermal menesmen, na paia proteksen insait long wanpela kontena DC sistem, na dispela i mekim bikpela eneji stoa kapasiti wantaim liklik on-sait asembli na wanpela moa standet deliveri straksa.

    More Energy in a Standard Container
  • Gutpela wok bilong kontena bilong bateri

    Wok bilong glasim ol bateri, menesim hat, painim paia, na lukautim lektrik i helpim long sapotim gutpela wok longpela taim insait long ol ples we i gat pawa ausait. I dipen long projek na prodak konfigurasen, ol sistem i ken kamap wantaim 'liquid cooling' o ol narapela 'thermal management' solusen.

    Safe Battery Container Operation
  • Fleksibel PCS Matsing bilong ol Skalabel Projek

    Olsem DC-sait bateri eneji stoa kontena, ol dispela sistem i ken bungim wantaim ol narapela PCS solusen bihainim ol samting projek i laikim. Dispela i mekim isi long skelim kapasiti bilong ol sola plent, win fam, grid stoa stesin, na ol bikpela C&I eneji stoa projek.

    Flexible PCS Matching for Scalable Projects
  •  

Yu mas makimKontena bilong putim bateri

 

  • 5MWh BESS Bateri Kontena
    5MWh BESS Bateri Kontena em i wanpela kontena bilong putim ol bateri we i gat wara long en na i gat kol na ol i wokim bilong putim bikpela pawa. Em i bungim ol LFP bateri modul, BMS, 'thermal
    Ritim moa
  • 6.26MWh Litiam Bateri Stoa Kontena
    6.26MWh Lithium Battery Storage Container em i wanpela 'liquid-cooled battery system we ol i wokim bilong ol bikpela -kapasiti eneji stoa projek. Em i bungim ol 'battery modules', BMS, 'thermal
    Ritim moa
  • 6.25MWh Bateri Stoa Kontena
    6.25 MWh Bateri Stoa Kontena em i wanpela wara-kol DC-sait bateri kontena we ol i wokim bilong ol bikpela-skel eneji stoa projek. Em i bungim ol LFP bateri rek, BMS, 'thermal management', paia
    Ritim moa
Bilong wanem ol Polinovel Kontena

 

Ol kontena bilong putim ol betri bilong ol projek bilong eneji we ol i ken skruim

 

Ol Polinovel bateri stoa kontena i save givim ol hai-kapasiti LFP bateri blok bilong ol yutiliti-skel na bikpela C&I eneji stoa projek — ol i wokim bilong fleksibel PCS matching, skelebol multi-kontena deploymen, na seif liquid-cooled operesen.

More Energy in a Standard Container

Moa pawa insait long wanpela standet kontena

Ol Polinovel bateri stoa kontena i save bungim ol LFP bateri rek, BMS, thermal menesmen na paia proteksen insait long wanpela kontena DC sistem — na i save givim bikpela stoa kapasiti wantaim liklik on-sait asembli na wanpela standet deliveri straksa.

Safe Battery Container Operation

Gutpela wok bilong kontena bilong bateri

Monitoring bilong ol bateri, 'thermal management', paia diteksen na lektrikel proteksen i sapotim gutpela wok longpela taim ausait long haus. I dipen long projek na prodak konfigurasen, ol sistem i ken kamap wantaim 'liquid cooling' o ol narapela 'thermal management' solusen.

Flexible PCS Matching for Scalable Projects

Fleksibel PCS Matsing bilong ol Skalabel Projek

Olsem DC-sait bateri eneji stoa kontena, ol dispela sistem i makim ol narapela narapela PCS solusen long ol projek rikwaemen — na mekim isi long skelim kapasiti bilong ol sola plent, win fam, grid stoa stesin na ol bikpela C&I projek.

Ol spesifikasen bilong kontena bilong putim bateri

Ol mak bilong ol kontena bilong putim ol bateri bilong Polinovel wara-kul.

Ol stretpela namba i save senis bihainim kapasiti, sel seleksen na projek disain — askim long wanpela datasit bilong wanpela spesifik model.

 
Paramita Tipikel Spesifikasen
Kain sistem DC-sait kontena bateri eneji stoa sistem (BESS)
Reit eneji 5 MWh / 6.25 MWh / 6.26 MWh long wanwan kontena (ol kastom kapasiti i stap)
Bateri kemistri LFP (LiFePO₄) — longpela saikel laip, bikpela 'thermal stability'
Sel kapasiti 280 Ah / 314 Ah klas prismatik sel
Sistem voltej ranj ≈ 1000–1500 V DC
Rot bilong mekim kol Liquid cooling (gutpela 'thermal management')
Tempereja bilong wok −30 digri i go long +55 digri
Saiklon laip Bikpela o wankain olsem 6,000 saikel (i dipen long disain-)
Banis 20 ft standet kontena; IP54/IP55 proteksen
Anti-korosen C4-C5 gred koting bilong ol ples ausait / klostu long nambis
Proteksen long paia Multi-level detection + suppression (pack / rack / container)
BMS / EMS 3-level BMS; EMS-redi, rimot monitoring
Komyunikesen CAN, RS-485, Modbus, Ethernet
PCS i wankain I stret wantaim bikpela PCS (ol i wankain long wanwan projek)
Ol aplikesen Yutiliti-skel, sola, win, grid, bikpela C&I

 

 

Ol aplikesen

Ples we ol i save yusim ol kontena bilong putim ol betri

 

Wanpela kontena pletfom i sapotim olgeta kain bikpela-skel stoa yus kes — stat long grid

sevis bilong 'renewable integration' na 'industrial backup'.

Peak Seving & Lod Shifting

Storim -peak eneji na discharge long taim bilong peak diman long katim ol diman sas na strongim saplai.

Energy Arbitrage

Sasim taim pawa i no gat bikpela pe na rausim taim prais i antap long kisim ol 'peak-valley price spreads'.

Grid Frekwensi Regulesen

Fast-responding kapasiti bilong frikwensi rispons na ol narapela grid sevis.

Sola na Win Integresen

Mekim gutpela autput we i save kamap gen na senisim jeneresen long wankain olsem yusim.

C&I Bekap Pawa

Gutpela bekap bilong ol faktori, data senta na ol bikpela fasiliti long taim bilong pawa.

Microgrid & Off-grid

Ol 'core storage' bilong ol 'microgrids', ol 'remote site' na ol ailan pawa sistem.

 

Sefti Akiteksa bilong Bateri Stoa Kontena

Layered Protection, Container to Cell. Sefti insait long wanpela bateri storage kontena em i olsem wanpela sen, i no wanpela samting tasol. Ol polinovel kontena i save bungim ol sefti meja bilong pawa, hat na paia long olgeta level bilong sistem olsem na ol i save painim ol asua hariap na putim long ples.

Level bilong sel na modul

LFP kemistri wantaim bikpela 'thermal-runaway threshold; monitoring bilong wanwan modul.

Rack level

Rack BMS wantaim voltej, karent na tempereja proteksen na katim.

Level bilong kontena

Sistem BMS/EMS, smok na tempereja sensing, na multi-stej paia suppresen.

Envairomen

IP-rated, anti-korosen banis bilong ol ples ausait na long nambis.

Menesmen bilong hat

Liquid Cooling bilong Iven Tempereja

Liquid cooling i save rausim hat long ol sel gut tru winim air cooling, na i save holim olgeta sistem insait long wanpela tait tempereja ben. Dispela i min olsem ol liklik senis long tempereja bilong sel-long-sel, pefomens i wok gut moa, na bateri i stap longpela taim long olgeta sisen.

Gutpela 'thermal control' i save stretim 'heating' na 'cooling' long envairomen, olsem na kontena i save wok gut long ol ples we i kol na i go long ol ples we i gat planti manmeri i stap long en — na dispela i save lukautim 'capacity' na 'cycle life' long laip bilong projek.

Yu ken toktok wantaim mipela long kisim moa toksave long prodak.

 

 

Ol setifikesen na bihainim lo

Ol kontena bilong putim ol bateri bilong Polinovel em ol i wokim bilong inapim ol setifikesen we ol i nidim long kisim global grid na maket.

 
UL 9540
Sefti bilong sistem
UL 9540A
Rot bilong paia tes
UL 1973
Sefti bilong bateri
IEC 62619
Sefti bilong sel na bateri
IEC 62933
ESS sefti
UN 38.3
Trenspor
C.E.
EU konfomiti
NFPA 855
ESS instolesen

 

Bilong wanem yu mas makim Polinovel

Polinovel: Wanpela kampani bilong wokim ol kontena bilong putim ol betri we yu ken wokim

Olsem wanpela dediket BESS manifektsa na saplaia long Saina, Polinovel i save givim ol samting we yu laikim,

faktori-i bin testim ol kontena bilong putim ol bateri wantaim sapot bilong ol enjinia stat long disain i go inap long taim ol i kirapim.

3GWH+

Kapasiti we ol i givim

Long olgeta hap bilong wol

Ol projek i kamap long olgeta hap bilong wol

OEM/ODM

Kastom kapasiti na PCS i wankain

Ful sapot

Disain → deliveri → bihain long-sales

 

Ol FAQ bilong Kontena bilong putim bateri

Q: Wanem kapasiti bilong wanpela Polinovel bateri stoa kontena i gat?

A: Ol standet model i save givim 5 MWh, 6.25 MWh na 6.26 MWh long wan wan 20 ft kontena. Ol kastom kapasiti na ol multi-kontena konfiguresen i stap olsem na olgeta sistem sais i ken go antap long MWh o GWh mak bilong projek bilong yu.

Q: Em i kol long wara- o em i kol long win?

A: Ol polinovel bateri stoa kontena i yusim gutpela 'liquid cooling', we i save rausim hat gut moa long 'air cooling' na i save mekim ol sel-long-sel tempereja i no bikpela tumas — na dispela i save mekim wok bilong bateri i stap wankain na i save mekim bateri i stap longpela taim. Ol narapela rot bilong stretim hat bilong san i ken kamap bihainim projek.

Q: Kontena i gat PCS insait long en?

A: Dispela em ol DC-sait bateri stoa kontena, olsem na PCS i stret wantaim ol samting yu laikim long projek. Dispela i mekim na disain i ken senis long ol narapela narapela pawa reiting na larim yu long bungim kontena wantaim ol bikpela PCS solusen. Polinovel i save givim tu ol PCS kontena sapos yu nidim wanpela AC-sait 'turnkey' opsen.

Q: Ol kontena i gat wanem ol setifikesen?

A: Ol sistem i kamap long inapim ol intanesenel ESS standet olsem UL 9540 / 9540A, UL 1973, IEC 62619, IEC 62933, UN 38.3 na CE, na sapotim grid koneksen na maket ekses long olgeta rijon. Askim mipela long konfemim stretpela setifikesen lista bilong model yu makim na maket bilong yu.

Q: Ol i ken stretim sistem long ol grid rikwaemen bilong mi?

A: Yes. Kapasiti, voltej, kol, komunikesen protokol na PCS matching i ken kamap long lod profail bilong yu, frikwensi-regulesen nid na rinewabel-integresen taget. Serim ol ditel bilong projek bilong yu na tim bilong enjinia bilong mipela bai kamapim wanpela stretpela konfiguresen.

Q: Ol bateri i save stap longpela taim olsem wanem?

A: Ol i makim LFP kemistri long stap longpela taim na strongpela 'thermal stability', wantaim ol kainkain disain we ol i makim long planti tausen saikel aninit long ol standet opereting kondisen. Trupela laiptaim i dipen long dip bilong discharge, saikel paten na sait tempereja — askim long datasit bilong waranti na saikel-laip figa bilong model bilong yu.

 

 

modular-1

Kisim wanpela Kastom Bateri Stoa Kontena Kwot

Mipela i wanpela bilong ol profesenel bateri stoa kontena manifektsa na saplaia long Saina, speselis long hai-kwaliti kastom sevis. Ol bikpela kontena bilong putim ol bateri we ol i wokim long Saina, i kam stret long faktori bilong mipela.

Polinovel i save givim ol gutpela -pefomens eneji stoa solusen long strongim ol wok egensim ol pawa bagarap, liklik

kos bilong pawa long rot bilong gutpela menesmen, na givim pawa we i stap longpela taim na i redi long bihain taim.

Painim ol rot bilong stretim hevi:BESS we i stap insait long kontena, PCS Kontena, Utility-scale Plant Solutions.

 

 

 

 

Mipela i wanpela bilong ol profesenel kampani bilong wokim na saplaim ol kontena bilong putim ol betri long Saina, na mipela i save givim gutpela sevis long ol samting yu laikim. Mipela i amamas long welkamim yu long salim ol 'high-grade kontena bilong putim ol bateri we ol i wokim long Saina long faktori bilong mipela.

Askim wok painimaut
Smatpela Eneji, Strongpela Operesen.

Polinovel i save givim ol gutpela rot bilong putim pawa long strongim wok bilong yu egensim ol hevi bilong pawa, daunim pe bilong pawa long rot bilong gutpela menesmen bilong pawa, na givim pawa we i redi long bihain taim.