tpiTok ples

Lithium ion UPS Bateri Bekap Sistem

Lithium ion UPS Bateri Bekap Sistem
Ol infomesen:
LiFePO4 bek-ap pawa we i ken go bikpela long ol data senta, ol fainensel senta, tren transit, na ol narapela misin-kritikel UPS aplikesen.

● Bikpela pawa densiti wantaim liklik mak bilong lek
● 10-15-yia laipspan bilong longpela taim UPS bekap
● Smat BMS monitoring na bateri proteksen
● Skelabol kapasiti bilong groim bek-ap pawa nid
● I no gat bikpela wok long stretim olsem ol 'lead-asid bateri'
Askim wok painimaut
Daunlod
Diskripsen
Teknikel Paramita

Lithium ion UPS Bateri Bekap Sistem

Ol i wokim 'Lithium ion UPS Battery Backup System' bilong givim bikpela pawa long UPS. Ol i wokim wantaim seif lithium-ion bateri teknoloji, BMS menesmen, na wanpela integreted rimot klaut menesmen sistem, na i helpim ol nupela fasiliti long kamapim gutpela bek-ap na tu i daunim wok bilong lukautim na laipsaiklon.

Wantaim module-level na rack-level konfigurasen opsen, sistem i sapotim fleksibel diploimen long ol data senta, fainensel infrastraksa, tren transit, na ol narapela bikpela envairomen we pawa i mas stap yet.

Scalable Lithium Ion UPS Battery Backup System
Em i gutpela long ol nid bilong yu long kisim pawa

 

Longpela Sevis Laip

Ol i wokim dispela sistem wantaim 10-15-yia laipspan, na i helpim long daunim taim bilong senisim bateri na i sapotim moa gutpela longpela taim UPS bek-ap pawa bilong ol bikpela wok.

Gutpela Bekap Pefomens

Redundant disain bilong ol ki komponen i helpim long daunim ol hevi bilong bagarap long wanpela -poin, na tu, gutpela bateri proteksen i sapotim gutpela UPS bek-ap pefomens bilong ol bikpela aplikesen we pawa intarapsen i no inap.

Fleksibel UPS Integresen

Ol i ken stretim dispela sistem long senisim bateri bilong UPS o wokim ol nupela bek-ap pawa projek, na dispela i sapotim 'flexible matching' wantaim ol UPS ikwipmen na ol narapela 'runtime' rikwaemen.

Kompak Modula Disain

Modular straksa we i stap long 'cabinet-' i helpim long yusim gut spes, mekim isi wok bilong putim, na sapotim 'flexible capacity configuration' bilong ol kain kain UPS bekap rikwaemen.

 
Spesifikasen

 

Rack-Level Konfigurasen Module-Level Spesifikasen Ol namba bilong modul Ol sais (W × D × H) Reit eneji
409.6V 50AH
51.2V 50AH
8 600 × 1000 × 2000mm 16.38kWh
512V 50AH 10 20.48kWh
614.4V 50AH 12 24.5kWh
409.6V 50AH
51.2V 50AH
8 20.48kWh
512V 50AH 10 25.6kWh
614.4V 50AH 12 30.72kWh
716.8V 50AH 14 600 × 1000 × 2300mm 35.84kWh
409.6V 100AH
51.2V 100AH
8 600 × 1000 × 2000mm 40.96kWh
512V 100AH 10 51.2kWh
614.4V 100AH 12 61.44kWh
409.6V 100AH
51.2V 100AH
8 40.96kWh
512V 100AH 10 51.2kWh
614.4V 200AH 12 61.44kWh
409.6V 200AH 51.2V 200AH 8 81.92kWh
512V 200AH 10 102.4kWh
614.4V 200AH 12 122.8kWh
204.8V 60AH 51.2V 60AH 4 600 × 1000 × 1200mm 12.28kWh
409.6V 60AH 8 600 × 1000 × 1500mm 24.57kWh
512V 60AH 10 30.72kWh

Daunlodim data

 

Konfigurim na skelim

 

VOLTEJ
Mekim UPS DC bas bilong yu

Ol 'series-modules we i konektim i save makim voltej bilong sistem. Yu mas makim wanpela 'cabinet voltage' we i wankain olsem 'UPS battery string voltage'.

4×51.2V=204.8V
14×51.2V=716.8V

MAK BILONG MEKIM WOK
Setim eneji na rantaim

Kapasiti bilong sel na namba bilong ol modul i makim eneji. Moa Ah na moa modul i save givim longpela bekap long wankain lod.
Ol sel: 50 / 60 / 100 / 200 Ah
Energy: 12.28 → 122.88 kWh

RON SAIT SAIT
Ekspandim taim lod i gro

Putim ol kebinet long paralel long apim olgeta eneji na rantaim; BMS na rimot klaut menesmen i save stretim ol.
+ Kebinet → + Eneji
→ + Runtime, wanpela 'fleet view'

UPS Bateri Konfiguresen Gaid

Wankain kemistri, BMS na akiteksa - narapela kain volteji, eneji na mak

Voltej ranj Sel kapasiti Eneji ranj Gutpela long
204.8–512 V 60 Ah 12.28–30.72 kWh Ol liklik rum we i gat liklik -voltej
409.6–614.4 V 50 Ah 16.38–24.5 kWh Pawa densiti / liklik hap graun
409.6–716.8 V 50 / 100 Ah 20.48–61.44 kWh Bikpela voltej span, inap long 716.8 V
409.6–614.4 V 100 / 200 Ah 40.96–122.88 kWh Bikpela eneji / longpela rantaim


 

Wanem Polinovel UPS bateri i stret long nid bilong yu

Fopela UPS prodak i save helpim ol narapela narapela nid. Mekim bilong yu aninit.

Scalable Lithium ion UPS Battery Backup System

Bikpela 'voltage'/kapasiti, skel long laik, 'lead-asid riplesmen long planti UPS

01

DATA SENTA

Turnki tripela-feis UPS + LFP bateri insait long wanpela kebinet - Data Senta LiFePO4 UPS Bateri Bekap Sistem.

02

HIGH-RATE

Sotpela, bikpela -reit 'discharge' wantaim bikpela pawa densiti-Hai-Reit Lithium ion UPS Bekap Pawa Sistem.

03

AI / HYPERSCALE

High-density AI compute backup-AI Data Center Lithium UPS Battery System.

04

 

Lithium vs lead-asid

 

 

Wanpela modular pletfom na ol VRLA string we i no senis

 

Wanpela samting Polinovel Scalable Lithium Lead-Acid (VRLA)
Inap long skruim Skelim kapasiti, voltej na paralel kebinet Ol string i stret, hat long skruim
UPS DC bas pilai 204.8–716.8 V long wanpela pletfom Limited voltej fleksibiliti
Laip bilong disain 10-15 krismas ~3-5 krismas
Mak bilong lek Bikpela densiti, liklik Ol bikpela, hevi benk
Helt bilong bateri Smat BMS + 'remote cloud monitoring' Limited; ol feilia i save hait
Mentenens Daunbilo Yu mas sekim oltaim
Instol Kebinet we ol i bungim pinis String bild + wiring

 

Ol aplikesen

 

Wanpela pletfom long ol bikpela sait bilong wok

Ol fainensel senta

Bekap bilong pemen, treding na sekyuriti sistem we i no inap long karim hevi.

Telekom na ol rum long arere

Ol kebinet we ol i bungim pinis wantaim 'remote cloud visibility' bilong ol 'distributed site' we i no gat planti wokmanmeri i stap.

Rel transit

Ol i bin sekim bek-ap bilong ol signaling, kontrol na stesin sistem.

Indastriel otomesen

Lukautim PLC/SCADA na ol proses lod long ol hevi bilong grid. Lukim C&I Solutions.

Haus sik na heltke

Seif LiFePO4 kemistri na multi-leya proteksen bilong kritikal-kea kontinuiti.

Ol data senta

Putim wantaim UPS bilong yu, o yusim 'turnkey'Data Senta LiFePO4 UPS sistem.

 

Kwaliti na setifikesen

Ol i wokim aninit long wanpela strongpela kwaliti-kontrol sistem na i gat ol intanesenel sefti setifikesen (IEC, UL na ol narapela). Ol ripot bilong tes na ol pepa bilong bihainim lo i stap sapos ol i askim long kisim projek.

Inkoming sel inspeksen

1

>>

BMS fanksen tes

2

>>

Tes bilong kapasiti

3

>>

Test bilong sasim / rausim

4

>>

Tes bilong insulesen

5

>>

Laspela inspeksen

6

Askim ol ripot bilong tes


 

A Trusted Leader In Energy Storage Innovation
 
 

Bilong wanem Polinovel

Polinovel (Shenzhen Polinovel Tech Co., Ltd) em i wanpela faktori-dairekt eneji-storage manifakta wantaim bikpela LiFePO4 ekspiriens na i gat gutpela rekot long senisim 'lead-asid long ol wok we i hatwok long mekim wok.

 
50+

R&D Enjinia

 
3GWH+

Kapasiti we ol i givim

 
80+

Ol kantri we ol i salim i go aut

 
3000+

Ol Projek i kamap gut


OEM / ODM:kastom voltej, kapasiti, kebinet, konekta, komunikesen na praivet lebol · enjiniaring sapot bilong sekim kompatibiliti na rantaim sais · pre-asembel, ekspot-redi long givim · fleksibel MOQ na kotim lid taim.

 

FAQ

Q: Dispela i narakain olsem wanem long Data Center LiFePO4 UPS sistem?

A: Dispela em i wanpela bateri kebinet (SPL/TPH/TP/TPL, 204.8–716.8 V, 12.28–122.88 kWh) we i save wok wantaim UPS bilong yu na i save skelim taim yu laikim. Data Center LiFePO4 UPS sistem em i wanpela 'integrated three-phase UPS' na LFP bateri insait long wanpela 'fixed configuration' (512 V / 120 Ah / 61.4 kWh). Yu mas makim dispela bilong 'voltage/capacity flexibility' na 'lead-acid replacement; makim dispela bilong wanpela 'turnkey' tripela-feis yunit.

Q: Hau bai mi makim stretpela 'voltage' na 'capacity'?

A: Mekim 'cabinet voltage' wantaim UPS DC bas bilong yu (204.8 / 409.6 / 512 / 614.4 / 716.8 V), na bihain makim 'cell capacity' na 'module count' bilong eneji we yu nidim. Salim UPS voltej, lod (kW/kVA) na taim bilong bekap bilong yu na mipela bai skelim wanpela model.

Q: Em i save go bikpela olsem wanem taim lod i gro?

A: Putim ol kebinet long paralel long apim olgeta eneji na rantaim; BMS na rimot klaut menesmen i save wok bung wantaim ol kebinet. Yu sais bilong tude na skruim bihain na yu no senisim disain.

Q: Em inap long senisim ol 'lead-asid UPS bateri bilong mi?

A: Yes - em i bilong senisim 'lead-acid (VRLA) na tu ol nupela 'backup builds', wantaim 'cabinet voltage' i wankain olsem UPS DC bas bilong yu. Salim UPS bren, model na DC voltej bilong yu long sekim sapos em i wok gut wantaim.

Q: Wanem ol setifikesen na pepa i stap?

A: Prodaksen i ron aninit long wanpela strongpela QC sistem wantaim ol intanesenel sefti setifikesen (IEC, UL na ol narapela). Ol ripot bilong tes na ol pepa bilong bihainim lo i ken kamap sapos yu askim.

Q: Yu sapotim OEM/ODM, na olsem wanem long MOQ na 'lead time'?

A: Yes - kastom voltej, kapasiti, kebinet, komunikesen na praivet lebol i stap. MOQ na 'lead time' i dipen long konfiguresen na setifikesen; tupela i konfem long taim bilong 'quote'.

 

modular-1

Salim UPS model bilong yu long kisim wanpela konfiguresen na kwot

Serim UPS bren bilong yu, DC bas voltej, lod na taim bilong bekap. Ol enjinia bilong mipela i save givim bek wanpela model rekomendesen, datasit na kwotesen, wantaim konfem bilong kompatibiliti pastaim long yu komitim.

 

 


 

 

Hot Tag: Skalabel Lithium ion UPS Bateri Bekap Sistem, Saina Skalabel Litiam ion UPS Bateri Bekap Sistem ol man i wokim, ol saplaia, faktori

Askim wok painimaut
Smatpela Eneji, Strongpela Operesen.

Polinovel i save givim ol gutpela rot bilong putim pawa long strongim wok bilong yu egensim ol hevi bilong pawa, daunim pe bilong pawa long rot bilong gutpela menesmen bilong pawa, na givim pawa we i redi long bihain taim.